Facebook
Twitter
E-Mail
XING
Search
  • Morgan Stanley, London

    Morgan Stanley, London - stringent technological and design requirements are combined in a harmonious, functional whole. The Mechanical & Electrical Consulting Engineer, MEIT Associates of London recognized, that the Kiefer INDUCOOL would offer the ideal solution for this project.

    Photos © Hufton+Crow
  • Morgan Stanley, London

  • Morgan Stanley, London

Chilled-Ceiling Panel INDUCOOL - Morgan Stanley, London

When Morgan Stanley opted to refurbish part of their London HQ located at 25 Cabot Square in Canary Wharf, the requirement was to provide high quality, flexible air conditioned space for client meeting rooms, conference and training rooms. With space air conditioning loads ranging from 45 W/m² to 170 W/m², this presented a challenge to find a product that would meet the demanding levels of comfort, a PPD of 5% according to ISO EN 7730 as well as the architectural requirements.

 

Technical Challenge

The Mechanical & Electrical Consulting Engineer, MEIT Associates of London, having successfully used Kiefer products previously, recognised that the Kiefer INDUCOOL would offer the ideal solution. In addition to the challenge of meeting the comfort requirements, the architect, tp bennett LLP required a product that could be integrated into various ceiling types, plasterboard, metal and wood, making it essential for the INDUCOOL to be finished in matching colours, these being white – RAL9016, Pearl Beige – RAL1035, Grey Brown RAL 8019 & Pantone 7463 to match the wooden ceiling. There was an additional requirement for RAL 5001, Morgan Stanley “blue” for the specialist areas.

Kiefer were able to meet both the technical and aesthetic challenge, producing the INDUCOOL in the required colours to provide an exceptional working Environment.

Read more in the project report ↓

 

+
Project: Morgan Stanley, London
Proprietor Morgan Stanley & Co. International PLC
Architect: tp bennett LLP, London
Planner: Meit Consultants LLP, London

Project report PDF download

INDUCOOL Morgan Stanley ↓

Do you need professional help? 
Kiefer Sales Contact »

 

Function chilled ceiling panel INDUCOOL

INDUCOOL cools with air and water. Most of the thermal energy is removed quickly and economically by cooling water. High-quality air diffusers ensure a high degree of comfort and optimum air distribution.

System advantages

  • Greater thermal comfort with low air velocity
  • Chilled ceiling panels require only 5-10% of ceiling area
  • Reduced energy costs by exploiting the cooling potential of outdoor air
  • High cooling capacity, up to 500 W/m
  • Temperature differences up to -14 K
  • Integration of cooling panels into cost-effective standard ceilings
  • A full-surface cooling-water system is not required

Kiefer Klimatechnik GmbH

Kiefer Klimatechnik GmbH is a leading company in the field of ventilation, air handling and air conditioning technology. Our range of services includes consulting, planning and execution of systems for thermal comfort and industrial air conditioning, as well as the associated installation and maintenance. For more than three decades, Kiefer has also been selling high grade ventilation components worldwide, such as linear diffusers, wall passages, displacement outlets, light and acoustic sails, chilled ceiling panels and concrete core cooling systems, developed in the company's own laboratories.

© 2024 Kiefer Klimatechnik GmbH